troubleshooting drummond shallow well pump

We had a really bad storm in which the power kept going off. I like that you said how like any other device at home, it requires care and upkeep in order to work as efficiently as you expect. 26 July 2015 Josephsaid:I have a shallow well pump for irrigation. You can also measure the pump's current draw using a clamp-on ammeter. to confirm an appointment time. Water pump would hum for approximately 30 seconds then stop. Unplug the valve and insert a pressure gauge into the valve to measure the air pressure. Pressure reaches cut-off, pump turns off. Can someone give me some advice please. 10 year old well pump that hasn't been ran in about 2 years. Bad Pressure tank ? Is there an easy way to break it free from not running for an extended period. Just a follow up (and not suggesting what I did fixed the issue) but I took the back metal panel off at the end of shaft and added some non-detergent oil to the shaft itself. If your switch wont turn on, this could be a sign your tank pressure is above your switchs cut-in pressure. How to install & wire a pump control box. Troubleshooting 10 Parts List Owner's Manual & Safety Instructions Save This Manual operating, inspection, maintenance and cleaning procedures. Well Pumps Shop All. Without a certain, I will assist them in hiring a specialist who can fix their water well pump at their convenience throughout the day. It could be a broken water line from the well to the house usually youll have a wet area between the well head and the house a bad check valve just above the submersible pump at the bottom of the well, a bad connector leaving the well casing or even a broken water line inside the well casing. To ensure that the pump works properly, keep the bottom free from sludge and dirt of all kinds. It was installed about 1 year ago and was working great , but now it delays in switching on when the tap is turned on. Motor will not start: 1. All Rights Reserved, Programmable frequency between injections, No; fill, empty, inject buttons only. 39 Problems and Solutions Need a gasket for shallow well pump 69302 for the . Another possibility is that the switch contacts are burned. Apologies for the delay. Someone trained in water pump technology will be able to make a repair or recognize the time has come for a replacement. It did look like there was already oil there, and the manual says its pre-lubricated, but I did anyway. The electrical contacts in your pressure switch can degrade over time. The well pump pulls or pushes depending on the type of pump the water from the well. Phoenix Homeowner: Where Does Well Water Come From? Could this be a problem with the pump because it was short cycling so often it seems like there is enough water in the well. If you have access to the suction lines of your water well system, inspect the lines for any signs of punctures or pinches in the lines. Replace diaphragms(4-000-010). Before trying to adjust the pressure control switch I'd check out the well flow rate itself. Actuator button is stuck in the down position. It turns off when the maximum PSI is reached. Watch out: for electrical shorts, fire hazards, shock hazrds - if a breaker keeps tripping, leave that circuit off until it's properly diagnosed and repaired. Drummond Description Keep your home supplied with a steady flow of water with this 1 HP Shallow Well Pump. You described a ruined water supply system that sounds as if it needs to be rebuilt, and what sounds like a shorted, burned-up motor or motor start capacitor or control. Call 623-582-5069 now! Complete DIY projects like a pro! Pump pressure control switch contact bouncing? Call the professionals at Mr. Rooter Plumbing! (Sept 6, 2014) Marc said:Previous pump failed after a nearby lightning strike. My submersible pump will not start. Reassemble into nosepiece and check for aspiration. Jim, I realize there could be another problem, such as with the pump itself, but I'd start by replacing the pressure switch. On 2020-03-18 - by (mod) - what to check when the pump won't start. No cost EMI. It is for information purposes only. 3/4 hp 230v 6.8 amp with max of 8.0 amp. Drain all the water out of the tank. Why Does My Washing Machine Smell When I Use It? This can also cause your pump to get clogged with iron bacteria. Its important to cut power when this happens so the switch wont burn out. Thanks for the help again! That said, if you encounter such instances, it would be best to call a professional repair service immediately to assess the source of the problem and find a solution accordingly. Then come to find out our pressure tank's bladder busted. I turned breaker off checked wiring, and then turned breaker back on the pump just hummed again and smoke came out of the motor. Could it be something else maybe? Is my pump bad or should I have checked bladder tank pressure? (June 27, 2014) Asad said:it needs a slight push to start the pump. At this time there are no componets to the well pump. It then sends it to the pressure tank, which holds the water under pressure until something in your plumbing system is turned on. drummond shallow well pump problems drummond shallow well pump problems. See CAPACITORS for HARD STARTING MOTORS for details. what do i do now?? You can also try gently tapping on the pressure gauge, the switch, and the tank. This typically happens, when the pump pulls from a shallow water source, it can bring sand and silt with it. Connect the wiring to the new switch in the same order as you removed them and secure the switch cover. 100% placement assistance. drummond shallow well pump problems drummond shallow well pump problems. Among the most pressing is the undeniable fact that keeping a natural water supply means you may have access to water sources that are less treated with chemicals, thereby making it a healthier choice for households. We thought it was the pressure switch and replaced it. getting water is no problem as there are many springs in this lake area. You don't say if the problem is the pump won't run or if it runs but doesn't deliver water. Now that you know what to look out for, you should be able to identify seven of the most common well pump pressure switch problems and even prevent them from occurring. Any ideas? Thanks! . Turn the adjustment screw left, or counterclockwise, to reduce the pressure switch's setting. February 25, 2023 . Learn from highly qualified experts. If you hear frequent clicking when no water is flowing, you have problems outside the house and youll need to hire a pro. Most, Verify that no GFI faults or outlets have been tripped. So first we rule out the pump: check the pressure control CUT IN setting against the tank's air pre-charge. lang: 'en-US' Watch out: If the pressure really is that high the situation is dangerous as you can blow the tank or piping, causing injury. I would check first for a silt or debris-clogged water pressure sensor port, I have a pedrollo water pump with a smart head attached. Whether it's an exposed electrical wire underground or if a fuse or circuit board has tripped, several problems can be traced to the well pump not receiving electrical power. If you see a spark and the pump starts, the pressure switch is the problem. Extremely frustrated! thinking it could be wiring short in the well? If your well water pump won't prime, it might be due to defective foot valves, check valves, or pipe leaks. Troubleshooting and Product Support . and the sounds that it normally makes with it working properly then you should be able to tell whether the pump is actually running or the motor is humming and not starting. With the right knowledge, you can do your best to prolong the life of your well water technology and keep it in good working order and even do some minor fixes yourself. Lisa For a more permanent fix, youll need to replace the switch. Again, I said it is about 3 1/2 years old and all the contacts I looked at look like the day it was put in. There can be several reasons for re-priming, one of the most common is evaporation of the fluid, and other reasons include leakage, pump movement and other maintenance related matters. See. First, turn off the power and double-check with a voltage tester. This is why many homeowners in the Phoenix area have shallow well pumps. 2849 S 49th Ave Phoenix, AZ 85043 Rubber insert has cotton plugs blocking flow, clean out cotton plugs or replace rubber insert (4-000-002). One of the main causes can be a leak in the well pump. Backflow Prevention Device Testing & Repair, Laundry Center Plumbing Repairs And Installation, Trenchless Sewer Line Repair Pipe Bursting, Backflow Prevention Device Testing Repair, Factors That Affect the Life of Your Water Tank, Well Water Maintenance and Checks You Can Do Yourself, How Your Water Pump and Pressure Tank Work Together. Pump It Up Pump Service, Inc is a residential well service contractor in Phoenix Arizona that specializes in "out of water" calls, well water pump repair, installation and rehabilitation of water well pumps and systems, well inspections, and well water testing services. Check tubing for holes. Or see WATER PUMP WON'T START FAQs-2 - more-recent questions and answers about a well pump that won't run. (function() { If you notice any change in it, such as constantly cycling on and off, its a telltale sign of a bigger problem. Checked the Electric line - no problems. Getting an annual water well inspection done may seem like an unnecessary expense when you dont currently have a problem. However, like any other system at home, it also needs attention and proper maintenance for it to function as effectively as you intend it to. It should be between 20 and 30 pounds per square inch. operating, inspection, maintenance and cleaning procedures. a lot of snow melt and water rise lifted the pump until it fell over. Intake line obstruction If the well pump or control switch makes no noise at all, just hums or clicks, and when the water pump simply does not run these diagnostic questions may help track down and repair the trouble. Check all the valves by operating them manually. Remove the old switch and the pressure gauge. Pull the contacts open and file off the burned and pitted areas using an ordinary nail file or emery board. Check the well tank pressure gauge to see if it is at least 40 PSI (or the cut-off PSI for your pressure switch model). Monday Friday: 7:00am 3:00pm. Valve body o-rings need to be replaced. the gage is reading is over 100ps, I bleed the tank and it went back to 60ty and the pump came on the pressure went back to 100ps which cut the relay off, no water getting to water heater. When you turn on the faucet, it shouldnt spit out water. The most common cause of well pump failureis due to electrical problems. Start with following the pump controls and wiring. Make sure all nuts and bolts get fastened. I'd check for a bad pressure switch or pressure sensor tube connected to the switch. If you disconnect the impeller assembly from the pump motor you can see which part is jammed, and what to replace. }; Also seethis water pressure loss diagnostic table: WATER PRESSURE TABLE 1: PUMP WON'T RUN diagnostics. Deep pitting and noticeable damage from burning will likely require that the whole pressure switch be replaced. Yes, a water pump that has running dry can suffer damage to a bearing or a pump impeller or even a pump motor causing it to fail to deliver adequate water pressure or flow rate. Thats where the pressure switch comes into play. I am in the process of installing a back-up generator and I need to know the amount of power consumed at start up by these systems. I tested it before putting it in the well and it was fine but now I cant get it to come on. Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia. Immediately turned pump off again. power is off now. Take a bit of time to check the health of your well pump and all the parts that get that water from the ground to your house. Drain the pressure from the system and drain all the water from the system. Pump It Up Pump Service, Inc Double-check that power is running to your well and that there isnt a short. The remaining kits will have limited stock, but will be monitored closely. Depending on the type of pressure tank, it could be an indication of a higher psi, but if your tank is showing pressure, then your problem is likely within your house and not a problem with the well pump or well. Email: info@PumpItUpPump.com What seems to be causing this? I went to the pressure switch and was able to manually restart the motor twice, once last night and once this morning. If you arent comfortable replacing your own switch, it is a quick fix for the pros, and youll be back to your hot showers in no time. My water just stopped. Download the troubleshooting guide that offers solutions for common issues. - Joe 8//3/12, Joe, check the amps - current draw when your pump switch sends current to the pump; If there is no current then there is an open break in the wiring; high current sounds like a seized motor.Similarly, with power OFF and the pump wires disconnected from the circuit above ground you can use a VOM to check for a short, open wire, in the pump circuit and motor.Unfortunately, unless you find a wire damaged or bad switch above ground it probably means pulling the pump and wiring again. MESSAGE. Over34 millionAmericans rely on a well for access to water. Check valve placed in upside down, black o-ring goes up into the handle. 2. Drummond 3000010K 2 to 10L Drummond microdispenser: 2 Plungers, 2 O-rings, 1 collet, 1 coil spring, 1 spring guide To replace the switch, start by removing the wires to the old switch and unscrew the switch. Richard:If the new pump runs (briefly so as to avoid damage) when connected to power separately then the problem is in the existing pump circuit or control. Troubleshooting Guide - Drummond Scientific Product Troubleshooting: Pipet-Aid & Nanoject Devices Pipet-Aid Model 4-000-110 & 220 4-000-110-TC & 220-TC 4-000-111 & 21 4-000-111-TC & 211-TC 4-000-100 & 200 4-000-101 & 201 4-000-105 & 205 & 205-A & 205-E 4-000-300 & 302 & 303 4-000-501 & 501-A & 501-I & 501-UK Nanoject II & 3 Models A perfect towel. If not heard, microswitch is broken, replace wire harness (4-000-046). Clean out check valve or replace (4-000-003). The motor doesn't get hot and sounds beautiful when running. never happened before so the hose may have tipped it over. A regular inspection from a professional is your time to ask questions, get insights, hear some first-hand knowledge and get the peace of mind of knowing youve taken steps to care for your home. YOu may not have done anything wrong. The best thing to do in this scenario is to call an expert and have it fully assessed for you to know what the real problem is. If the submersible well pump won't start, there could be one of three things wrong. When opened, rinse float and shell with water or alcohol. Being able to troubleshoot water pump problems on site can save time and money. When the tank pushes out enough water to trigger the pressure switch, it then allows more water in from the well pump. Moreover, the check valve could be malfunctioning as well. b. You may also need to clean the bottom of the switch itself. Your electricity bills could rise for no reason. I am over it! On 2020-03-01 - by (mod) - water just stopped. Please see your question and my detailed reply now found near the end of PUMP CONTROL STATUS INDICATORS Diaphragm inside pump is split or dried up and cracked. Listen for slight click when buttons are first pushed. (Jan 21, 2015) Ray said: My pump (from tank to house) has been running intermittently and actually shut down twice in the last 24 hours. So, if a pressure switch is set for 40 to 60 psi when enough water is drained from the tank to reduce pressure to 40 psi, the pressure tank will turn on to collect water from the well through the water pump and turn off when the pressure in the tank reaches 60 psi. I am guessing in that direction because at the end of a pump cycle even if the pressure sensor of the switch is not working properly I wouldn't expect pressure sense to drop so far as to fall below the cut-in right at the END of the pump cycle. It's pretty natural to think it's just for the month's usage. It just hums and doesn't pump water. I don't see any leaks or damage and the pump is primed. Please help. But it does require more technology to maintain and repair if you want to keep that dependable supply running through your faucets. drummond shallow well pump problemsplayeras por mayoreo en los angeles caplayeras por mayoreo en los angeles ca When a well pump turns on, youll hear the clicking of the pressure switch opening and closing. I have a question related to water pump, actually my water pump is not creating a required pressure as we have started our pump after some month's so what can we do? Review our troubleshooting guides for product information, common fixes, and how to ensure optimal performance for your Drummond Scientific device. I can re-start it by depressing the disconnect switch. Ken the motor could be frozen - it may be freed by a complete disassembly and cleaning of the pump motor. Well water pump won't start or won't run, diagnostic FAQs: This article provides answers to frequently-asked questions about water pumps or well pumps that will not start or will not run. My well tank bladder ruptured and caused my well pump to constantly short cycle do not know how long this went on for work. When unpacking, make sure that the product is intact. Be sure to follow our blog. Minimum two gallons of water. Push against the top of the tank to rock it slightly. How? For instance, if your piping is of the wrong size, it can cause a leaky connection. Low water pressure. If the clock works, youll know the issue is with the pump and will require a service call to a. My sisters good pipes appear to be having plumbing issues since she isnt getting clean water. I'm not sure if we're seeing rust, a simple leak, a failed tank, mud or debris contamination of the water supply or what. First shut off electrical power to the water pump system. A new pump on an existing well begins to pump water and build pressure 35-40psi in the collector tank. Label each of the wires coming out of the switch relay and remove them from the faulty switch. Previously, we covered impeller problems for centrifugal pumps [/blog/centrifugal-pump-not-pumping-as-much-water/]. then the problem is the wiring, or pump, or there is a broken-open water line Tom Has this problem (pressure boosting pump won't turn on) always been the case since original installation, . Clean the hosepipe you're going to use with freshwater. As with anything in your home that has power running through it, you should turn off the breaker in your electrical box to the pressure tank and well pump before working on it. On 2020-03-01 - by (mod) - HITACHI WM-P250XS Water Pump troubleshooting & repair. If you are familiar with your pump Pump is at leat 10 years old. The most common problem in a household is turning on the water faucet, and no water comes out of the tap. tube near the pressure tank. For Residential Services: Close off the valve that goes from the pressure tank to the plumbing of your house. From time to time, well pump repair or replacement will be necessary. when turned on, it hummed for a moment then stopped. Our Comment Box is provided by Countable Web Productions countable.ca, Click to Show or Hide Citations & References, water would work for 5 minutes at a time, then after 10 minutes would run again. A bad pressure tank can cause your pump to kick in and out repeatedly while running water. hardly any pressure of water in our showers etc. Need assistance with the the Nanoject II (3-000-204/205A/206A)? After filling the pump with water, shut its control valve, and loosen the prime plug. I have a question. If it isnt, make sure your filter isnt clogged or in need of a change. Type of Service Needed Lead-free fittings and drinking-water-grade rubber seals make this system appropriate for potable water. When things go wrong, its important to understand how to complete shallow well pump troubleshooting, so youll be prepared to resolve the issue yourself or hire a professional service provider to come to your location and fix this for you. You will not receive a notification when a response to your question has been posted. Remove the screw at the bottom of the pump control cover and lift it off the box to disconnect it. Once youre sure the power is off to the pressure tank you can test with a non-contact voltage tester follow these steps to perform basic maintenance on your pressure switch: This is a great maintenance task to do on a bi-annual basis. Try running some water elsewhere in the building to reduce pressure below the cut-in level. We recommend our users to update the browser. When the pump motor hums but doesn't actually run, that sounds like a failed pump motor. Ill let her know about this so that she can have competent water well pump repair in the future. What is wrong with it. - Anon. improvements, actual product may differ slightly from the product described herein. Take it to the store and buy an exact replacement. WATER PUMP WON'T START FAQs at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice. If you find the pressure switch is bad, test the pressure tank to make sure it isnt waterlogged (see Problem: Pulsing Water). Fuel Transfer Tanks & Pumps Shop All. The DC battery is charged from line voltage (until a power outage) but the power the unit produces from the DC battery is converted back to normal or standard AC power. The Nanoject IIIs auto HOMING feature will eliminate the need to rehome the unit as in the Nanoject II. Primed pump and turned on breaker pump just hummed about 10 seconds and shut off. It can also be due to corrosion of the water well casing, liner, or screen, causing holes. Basically there are two problems. Here are nine of the most common issues you will observe with your pressure switch. However, if there's a leak in the suction line, air continues to be drawn into the pump, never allowing it to release enough to create that area of low pressure. 7. The contacts close briefly, pump just starts to turn, then everything stops and pressure falls. Not sure if your pressure switch is bad? You can test the air fill valve with an air pressure gauge. BenG, On 2020-03-11 - by (mod) - smoke came out of the motor. This also happens if we run the faucet in the tub or the washer. A shallow well jet pump's pressure switch regulates the amount time the pump motor runs. po.src = 'https://apis.google.com/js/plusone.js'; Note: appearance of your Comment below may be delayed: if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. My water pump froze and now when I turn it on. Find the prime plug (which is typically on the head of the pump). Search InspectApedia.com for We also provide an ARTICLE INDEX for this topic, or you can try the page top or bottom SEARCH BOX as a quick way to find information you need. Daniel. However, to keep enjoying those benefits, its a must to ensure that your water well and its parts like the pump continue to function well. Terri I suspect either a wiring error or capacitor of wrong specs. We appreciate you alerting us to the fact that one of the most important is the incontrovertible truth that maintaining a natural water supply may provide you access to water sources that have undergone less chemical treatment, making it a healthier option for homes. If your installer put in a new pressure switch and did not fool with its settings, the CUT IN pressure is either 20 psi or 30 psi. Anthony If you press the valve down and get water, then you've most likely got a ruptured bladder in your tank. Unit needs to be recharged. Now available for the Nanoject II is the new Digital Control Box which has all the functionality of the original control box but now features a user friendly, easy to read touchscreen. Leave the pump off in that case so as to avoid burning up the motor or damaging the impeller . Points stay closed. The pump must be suspended from the handle or be placed on the bottom of the basin. Turning the large nut changes the overall range higher or lower. Poor seal around filter; use Drummond filters (4-000-051), No sound from motor when buttons depressed, Filter has been wetted. Then check the voltage delivered by your solar converter as well as its current capability (amps) against the pump specs. TC gasket missing in nosepiece, requires one on each end of filter (4-000-057). Our water would work for 5 minutes at a time, then after 10 minutes would run again. Shop for Well Parts & Repair at Tractor Supply Co. Buy online, free in-store pickup. Continuous tripping could be caused by a broken wire leading to or inside the water pump. They will have the experience and correct equipment to determine whether the problem is due to a faulty water well pumpor if its a secondary system that will require repair or replacement. As the pressure switch ages, these components can weaken and malfunction, at which time replacement is necessary. And if your well pump uses a separate start relay (separate from the pump pressure control switch at the water pressure tank) check for a bad start/run capacitor. by (mod) Do you mean dis-assemble the water pump (answer: never except during repairs), or do you mean turning on water or tuning on the pump (answer: power to the water pump is in most installations always on, and the pump operating cycle or on-off cycle is controlled by a pressure switch. If you can open any pressure relief valves, do so now. You must have a good sense of the using materials. To replace the switch, start by removing the wires to the old switch and unscrewing the switch. IF I've got this right, when you connect the pump while it's out of the well it runs, but when it's in the well it does not. Or your well itself cannot keep up. I can start it with the manual switch and it will run fine . Humming sounds like a seized motor. Pump system has been installed and running for 2 years plus. I have a large amount of orange/brown mud that has oozed out of the rubber hose that connects between the tank and the top priming valve. Red Lion is pleased to announce that Shallow Well Repair Kits are now available for the RL-SWJ Series and RJS-PREM Series. My problem is that when the pressure drops through the cut in point, the switch "tries" to trip. - 2 line jet pump hums but doesnt turn over. Plug in power supply/charger and use unit while it charges, use only power supply/charger 4-000-065 (-066 Euro; -066-A Australia; -066-E for UK). Does the lack of water cause the smoke or is there something else wrong? The tank is then refilled to its maximum capacity, which is measured by the pressure gauge on the tank, and then it shuts off again. A simple cause for this can be a tripped circuit breaker, consequently shutting off the power of the pump. Our water worked good for a day. So, for you to learn how to fix those problems by yourself keep this guide handy at all times. Please contact the franchise location for additional information. So then I pulled the well pump figuring it may be the check valve so I replace the check valve and reinstall the pump in the welland two weeks later it started doing the same thing again. Pressure control switch isnt turning on the pump - when using the manual cut in switch the pump isnt turning on either, however, if you manually use a screwdriver and push the contacts down you can get the pump to engage. Basically, you start out with the tank drained. Best Value: Flotec FP4012-10. We have a pressure control switch lever (as shown above) that we need to re-gauge if we run two faucets (or demand too much water) at one time. Do not install the pump by suspending it unsupported from its delivery pipe or power cord. The problem could be that there's no water in your well. Check the actual system, pressure independently. Could there be something going on down at the water source? This information is not intended as an offer to sell, or the solicitation of an offer to buy, a franchise. Second, check the overload protection by checking the circuit breakers and third, check if the pressure switch is damaged. The Pump is equipped with a shockproof plug according to regulations. is it possible that a pump control or above ground pump has been wet or flooded or shorted out? A malfunction in your switch could indicate a problem elsewhere in the system. Gary,About using solar power to run the well pump:First check that all of the wiring is intact, continuous, without shorts or breaks. Something easy and stupid ? What next? Please bookmark this page to make it easy for you to check back for our response. The intake line should be both the recommended size and at least the same size as the discharge line Walk the intake line from the source to the pump and be sure there are no kinks If possible use a rigid intake line. Well pump hot to touch. For municipal water supply, the water pressure is mainly controlled by the city or township, although there are a few internal plumbing issues that can decrease pressure. Just installed brand new Deep well Jet pump. Tools required for assembly and service may not be included. I didn't have a problem with water before installation just replace the pump as I had a leak in the bladder.