220V clocks have 5 terminals, 110V clocks have 3 terminals. When I turned it back on now the pool clock goes backwards. how can I turn the time bar back down to the 6 oclock point so my timer will turn the lights on some how it is in the 2 oclock position an will not turn on automatically, Your email address will not be published. In this case its likely the On/Off trippers, loose wiring, the clock face not being located correctly or a faulty pump. Hi Chinh, if the clock gears are not moving, check the two small white wires going to the motor, on the reverse side of the timer mechanism. If none of the above suggestions resolves your issues or the issues continue to persist, it may be a good idea to purchase a new Intermatic timer for your pump. 2303 RR 620 S #135-378 Lakeway TX 78734 USA (737)-210-8494 Sign in or Register Compare Gift Certificates Advanced Search Search Keyword Required Categories Automatically search sub categories Brands Search By Price Price Range From to Search By Setting A qualified person would check there is power to the timer and then bypass the timer to see if the pump worked. Any advice? Grab it, pull it towards you, move it around then place it back down. I have to reset the time every day. Same way, WD-40 or any light lubricating oil. Check that the TEST button has not popped out. Since you have another switch in between the breaker and clock, the breaker will lose power when the switch is turned off. My timer runs, then after it reaches the off tripper, it stops, and never goes past the off tripper. For Sale: 2 beds, 2 baths 1152 sq. Elite Swimming Pools TV 4.08K subscribers Subscribe 1.1K Share 97K views 3 years ago MIRAMAR Pool timer. Same goes for slipping timer dogs! Home / Pool Repairs / Equipment Repairs / Intermatic Pool Timer Troubleshooting. Im wanting to use T101 to wire my above ground pool pump. The trippers will "trip" the analog clock to turn on and off automatically at the set times. Power surges could be to blame. },
After I replaced the motor with a 60Hz 277/208v motor the timer ran, but gained 1 hr/day. Replaced timer motor on a T10404R Now time is running fast about 2 hrs. You can replace the entire mechanism or the gears. Take them off and inspect them. Turn the manual on/off switch. Wired correctly, #10 wire, nothing. Any thoughts before I run out to replace it? "identifier": ""
The green tripper trips the mechanism closer to the center of the dial and the gold tripper trips the mechanism towards the outer edge of the dial. My timer clock does not run and the manual on off switch does not turn off the pump motor. The timer appears to be working fine (keeps time). So out comes the soldering gun and the shrink wraps and that did the trick. You need extreme care in this next step. Hi David, I suppose that you could wire the T101 from the outlet, but Im not sure if that is in accordance with code. Pools are not cheap! ), you should be able to discern if this is the problem, which could mean a new clock. Filter pump is ON at all timer Timer contacts welded Replace timer 5 . Is it possible to do this by loosening the timer screw a bit? Move the switch and see that they separate when off, and come together when on. Is it Necessary? Posted by 4 years ago. Not sure if you still answer these but I have a weird one for you. My pool timer is in the off position and it is still running. Thanks. I currently manually turn it on and off. To set it, you just move the on/off "trippers" where you want them. If all looks tight and no foreign objects or insects are found to be in there, and the switch mechanism does not look worn (the silver part next to the tab you manually flip to turn on/off), then its probably a failing timer motor. They are: Heres how to troubleshoot a mechanical pool timer step-by-step: It goes without saying that you should be qualified if you intend on working with live power. "@type": "Person",
I manually turn it on timer is running, it will trip pump OFF. The pool pump can run for 16 hours every day, which means not only will you save electricity, but you also will recover the cost of the timer within 2 years. Thanks! Another time clock that you can plug your pump directly into, and then plug the timer into the outlet, is the 24-hr Timer https://www.intheswim.com/p/24-hour-pump-timer (currently we are out of stock, but you can find at any home or hardware store). If the motor gears are not turning, check the wire tightness (Breaker off first), and depress the tab at top to inspect the rear of the mechanism, to see if anything looks funny back there. Hi Ryan, that sounds like a bad motor or a broken gear, you can replace just the motor, or the entire clock mechanism. Once you remove the water, you can use your pool brush on a pole, to gently push the pillows back to the center. Intermatic time clocks are the workhorse of your pool equipment collection, and oftentimes outlive the equipment they control. Hi there, Gently tighten the screws to securely hold the dogs in place. If its not, it wont work properly. did i do something incorrectly? Perhaps bad wiring or a bad breaker is to blame. Is there a control board, PCB in the panel that could have problems? It would not reset itself and could not get power back to the timer. Electricity is dangerous and can kill you if you dont know what youre doing. Hi Rhomell, are you sure you got the correct trippers? Theres really only 3 causes as to why your pump wont turn on/off. My pool pump timer is not working properly. Intermatic timers are common among pool owners and typically last a long time, but they also can come with problems and may need to be fixed. No matter what caused the issue, there is typically an easy fix! If all looks well, and the gears are still not turning, you may need to replace the mechanism. A power surge may have taken out the timer or the pump. "description": "Frequently asked questions about Intermatic T104 and T101 timeclocks, used to power many loads, and the primary timer used for swimming pool pumps in America. Much like your timer pointer, the trippers can become loose and move around as well. JACUSTOMER-hlvgjzll- : I have just sprayed WD-40 on the switch coils that move the lever that the trippers hit. You will first need to adjust the time on the timer first. And does the switch look worn, where the tripper engages? My timer doesnt seem to be working or my pump in either speed. This product can be controlled with your voice through Alexa-enabled devices such as Amazon Echo and Amazon Tap. Not two OFF trippers? My original timer worked for 5 years then the clock stopped and I heard no sound. Thanks Reid. Clean the gears with a toothbrush if you see debris or gunk in them. I had to replace my 2 year old intermatic timer motor this season as gears werent turning. "url": "https://blog.intheswim.com/"
"mainEntityOfPage": "https://blog.intheswim.com/intermatic-pool-timer-troubleshooting/",
Now try to jiggle it on and off. the timer was directly plugged into a gfci and the pump directly into the timer. Hi Phil, usually the OFF dog may not be fully pushed onto the dial, or if you examine it closely, it might be worn. "author": {
My timer works good it turns on and off when I set the time. If you cant, is the manual switch stuck or jammed? If you have both pins take notice of there position and then come back in a few hours and see if they have changed from the spot they were in when you last looked. Terminals 2 and 4 are used for wires going to the load (pump). My time clock has an ant infestation! everything seems to be working correctly, but i can not turn the pump on or off by tripping the mechanism. "publisher": {
AJH Trade Group also participate in other affiliate programs. Pool pump timers can last up to 20 years, depending on the model. Give it a little squirt of WD-40 or similar lubricant. Ask Your Own Pool and Spa Question Trippers are not installed properly Re-install trippers on dial 2. The problem was the connections I made inside my main electrical panel, I used romex wire nuts to attach the solid core #10 wire that I used to hook up the timer to the existing stranded #10 wire and it didnt make the connection so to speak. Also, once it reaches the tripper, the gears in the window no longer move. Read full answer 2/14/2023 3:20:07 AM Maybe 2/wks ago I replaced it with a new timer, and it's doing the same thing. Using Your Timer to Optimize Your Pool Pump Download Article 1 Check the chemical balance of your pool. Ive got the opposite problem than a lot of people. Welcome to Pool Spa Outpost! I reset the breaker and tested the GCFI and I have 240V going in and out of the timer still but my pump isnt moving. HI Ben, yes just remove the OFF tripper, and the clock will always be ON. When you flip the switch does it separate and reconnect the tabs? It is still moving and it will trip off but not on. My intermatic timer is about two years old as well. And there you have it, the quick and easy ways to troubleshoot common Intermatic pool timer problems. So either the tripper is broken (or installed out of alignment) or the tab (s) on the on/off switch are broken. Look to see if the clock is set to the correct time. Check out the wiring diagram that comes with a new timer, or is printed on the door of the timer box. Hi John, the trip mechanism on the clock, the switch, could be worn to the point where the tripper does not make good contact. The most common pool timer used for inground pool pumps is the Intermatic time clock. Some white lithium grease on the switch can help in some cases. If not, the motor may be failing. Any suggestions as to how to test clock feed? As you release the dial, you will feel the gears engage. NEW CONSTRUCTION. Also be sure that the ON dog is not actually an OFF dog, and that it is tightly secured to the dial edge and pushed all the way onto the dial, and straight. Morgan Burley Proceed to step 4 to check the timer itself. Also I have rotated the dial several times to trip on and off hoping that it lubricates the problem lever and dusts off the coil well. I copied the wiring config exactly and my clock gears still arent moving, so now Im thinking the wiring was wrong all along. Sometimes we suspect the timer is the issue but it turns out its really the pump or the wiring between the pump and the timer. If you need to set the time, you will need to take two fingers and slightly pull the wheel towards you and away from the back of the timer box. There is a second switch between the breaker and the timer. Line is incoming, Load goes to the pump. You need that 8 hr run in just the summer . So what you will want to do now is to look for the circuit breaker panel and locate the circuit breaker for your Intermatic Pool Timer and then make sure it is set to the on position. P.S. Yes, likely a short to ground. Check the diagram on the box label, and connect the wires from the breaker to the terminals marked Line, and the wires that go to the pump connect to the terminals marked Load. I mean you could go out and buy the timer for the electrician but you will need his experience to get it installed correctly. Does the motor gradually start running slowly? Hi. One morning I noticed my pool didnt automatically turn off. I bought a new motor for mine after 20 years and learned about this the hard way. If you look closely (with a flashlight and your glasses! Does this mean I need a new T104, or is there a replacement manual on/off switch? I dont see timer gears rotating on any power going to the pump or salt system. The same happens prior to the timer reaching the off tripper. Using a tester i noticed that there is no power going thru the lines for the pump and salt system. Take them off and inspect them and look for twists in them. "@type": "ImageObject",
The green tripper is a recent thing - maybe the last 3 years they have been included in the replacement bag. Voltage is 243, frequency is 60hz. You off course will want to adjust one time pin at a time. Your pool timer and pump will be on its own circuit and have a dedicated circuit breaker or GFCI (ground fault circuit interrupter). 110V or 220V? In this post, we discuss a few quick and easy ways to troubleshoot your pumps Intermatic timer clock problems. To check this, carefully inspect the gears for missing teeth and make sure they all freely turn. Now it worksbut its really fast. Now, Im going to order some additional timer clips. How do you know if your pool timer is bad? Hi Davy, Inspect that the gear behind the timeclock dial, is turning (very slowly), and that nothing is caught up in the gears, like sand or a lizards tail, or bugs, etc. Can I spray the timer while there is electricity going in the timer box? Move the start and stop pins to appropriate times for swimming pool filter operation. Pump operates off schedule Power failure earlier Reset timer Breaker was OFF for some time Reset timer 4. Because a pool timer is an electrical timer with mechanical aspects, the clock dial portion of the timer pulls out to set the time. Just turn the timer wheel until the correct time of the day is aligned with the timer marker that is mounted in front of the wheel. what causes timer on/off pins to bend and how can i prevent timer pins from bending. Thanks. But eventually, like all equipment, intermatic clocks wear out and need to be replaced or repaired. You can always call us at 815-675-7000 M-F 8am-4:30pm CST and speak with a live technician. The problem I am having is the timer clock moves correctly, but when it gets to the ON or OFF mark it stops and does not make the switch turn ON or OFF. These clocks determine when your pool pump turns on, and how long it runs. It I set the timer again it will jeep time until it gets to the next dog ear. I called Intermatic and there is nothing you can do except check it every time you have a power loss. I believe its the manual on/off switch that is the problem. If test shows that timer is not turning ON-and-OFF, then timer is bad or trippers are worn and need replacement. We had a storm last week and the yard flooded my pool so I went and switched the pool off at the breaker so it would not come on with the tabs until we were able to handle the pool. Hi Andy, when a clock is running slow, we might assume power outages, but when it runs fast, we might assume either a 60 hz (US) timeclock hooked up to 50 hz power service (Europe), or vice-versa, or a manufacturing defect in the gear tolerances could cause a synchronous motor timer to run fast. I am using the breaker to turn on and off the pool pump. Sometimes those are looped back to the control box. i have a P1121 intermatic timer connected to a hayward above ground pool pump. Be sure they are intact and are connected firmly on both ends, to the front terminals and to the motor on the reverse. I see that the Intermatic WG1573-10D Replacement 208-277 VAC, 60 Hz Motor, is compatible with For use with T102, T104 and WH40 clocks by Intermatic. If there has been a recent power outage, the clock will have stopped and youll need to reset the clock to the correct time. You can always call us at 815-675-7000 M-F 8am-4:30pm CST and . Hello, I notice today that my pump wasnt running so I opened the pool breaker panel where the timer is and noticed the breaker was tripped. Not sure if i need to check out the wiring, but it is a bit frustrating. Jun 3, 2013, 10:07 AM You will have ON trippers and OFF trippers, You can place an ON at Noon, and OFF at 1:00 for 1 hours operation, If you manually turned it back on at 3:00, it would stay on until the next OFF tripper (1:00). Then turn the breaker, that the time clock is connected to, off and back on again. I turned the breaker off and back on and still not working. If you loosen the hold down screw to much it could separate from the timer pin. White is usually neutral (for 115V power), and black/red are usually hot, but sometimes people dont always use the correct wire color. Turn the power off at the breaker box and carefully remove the wires to the clock. Hi Catherine, turning it on manually should not have damaged anything, so go easy on yourself It might have just been time to go. Simply screw it back into place until its snug. Related Reading: Should You Get a Pool Pump Timer? I replaced T104 timer it runs and shuts off with no issue but once off the timer does not move or turn back on. Im ready to send my back for a replacement. The motor is running and I turn off using breaker in the electical box, I put a new timer in and does the same thing. Since it came out of the box today, it probably is not trash in the gears.It seems the plastic gears and/or the coil in the clock mechanism are not strong enough to engage the on/off points or not for long. Yet another reason why timers dont work properly is the yellow clock wheel is not located or seated properly. Learn more about pool care and repair. Theres an issue with the wiring between the circuit breaker and the timer. I bought new trippers. The pointer should point straight down, and you pull out on the dial, to set the correct time, aligning the current time with the pointer. To adjust the time you will first want to look for the time bar that is mounted in the middle of the timer wheel. March 16, 2022 by WildRiverCountry. BUILT BY HAND IN QUEENS, NYC. Hi Tyler, maybe the dial is now pushed forward, far enough to where the trippers do not contact the switch? When the power goes out, the timer stops. It sounds like the Line and Load wires are reversed. Dead as a door nail. After a few days its off by 6 or 7 hrs but still turns on and off fine any suggestions? MLS # 6354744 Just moved into my house and the pool pump continues to run even after tripping the timer mechanism. If the pool timer is not keeping the correct time or losing time, there may be a simple fix. If youve followed this guide or arent confident in diagnosing the issue yourself, seek a qualified pool technician or electrician. It just stays at that time. I have an intermatic T20004R and my timer is working because it is keeping the correct time. "dateModified": "1/10/2020",
No high loop or air gap in the old under-the-sink dishwasher drain, Consider radiant underfloor heating system, Several Important Steps Homeowners Can Take To Protect Their Furnace, 4 Kinds Of Chemical Drain Cleaners That Clear Out Drains and Their Hidden Dangers. How about the GFCI outlet TEST button, is it tripped? I have the Intermatic T103 autotimer on my pool. Is the ON tripper all the way pushed onto the dial? Or the switch can suffer wear over many years, and might not make solid contact. I have replaced the trippers, but the problem persists. Thanks in advanced. Ft. 750 Joshua Dr, Hollister, CA 95023. Hello Davy, Terry here again. As an Amazon Associate we earn from qualifying purchases. For additional tripper pairs on CLOCK-DIALorder 156T1978A. If they are not moving then you have an issue. This will disengage the dial and allow you to spin it in either direction. If you dont think the mechanism is the issue, move onto the next step. DEWENWILS Pool Pump Timer, Digital Timer Box, 2HP 40A 120-277 VAC, 7-Day 20 ON/Off Programmable Timer Switch for Water . It started lagging again a week or so ago. I looked to see if the gears on the timer are running. Flip it from where it is now, to the opposite side. Timer not tripping pump on. . The terminals on the wires aren't tight. Hi, hope you are doing well. Could be small bugs, or dirt, or both causing the problem. You can also apply some of the troubleshooting steps to other brand timers. If your pool pump timer isn't working, it's likely because of these explanations: Broken timer motor Power outage Circuit breaker problems Loose timer tags Disconnected wires Incorrect time of day Broken internal timer In this article, I'll discuss several reasons your pump's timer won't work. So, the off dog just slips across the switch and doesnt allow the switch to turn off the motor. Some of the most common issues for a pool pump timer not working are: power outage, incorrectly positioned yellow clock wheel, loose timer trippers, faulty internal timer, and a worn-out motor. What Im wanting to do is just disable the turn off/on and just keep power 24/7. There are simply things you can do yourself like adjust the timer pins and set the clock on the timer. For extra safety, shut-off the Pool breaker on the main home panel too. David, check the wiring, the power in and power out wires may be reversed. If the timer manual switch isnt jammed and freely moves into the On and Off positions, then there is either no power to the timer, the timer itself has a fault, there is an issue with the wiring or the pool pump is faulty. I have noticed that the gears turn when the pool pump is on but they do not when the pump is off, which surely is the reason why it is losing time. If your pool pump timer is beyond repair, call a professional to replace it. Tighten down all brass screws securely, to hold all wires firmly in place. South Sea Island Accommodation: Was a good island when all the day trippers left - See 160 traveler reviews, 205 candid photos, and great deals for South Sea Island Accommodation at Tripadvisor. Second thing to check is the dial bent or warped, in that area where the on tripper is? Or may be bent and not come together. First you want to make sure there is actually power getting from the power board to the timer itself. I bought a new timer and replace the T104 timer clock. And Ive noticed lately that the ON is not functioning all the time. . Step 3 If you dont have the voltage here you have an issue with either the wiring or the breaker. I look through the window of the panel and see the gears running well. Eldon, the breaker should not be bad, but the timeclock may be wired incorrectly. Depends maybe on what it is getting stuck on, or what is catching the tripper, and are the motor gears still turning when it gets stuck? If I manually push the lever, it moves without much pressure. Align the bar with the current time and push it back into place. How can it keep time if lever is in off position (manual lever). To check this, try to pull out the clock dial and then move it to the correct time and press it back down again. Beverly, it could be, but the cost of running wiring to the garage may be more than replacing it every 15-20 years. They should be straight, if not, replace them. Replace the plastic insulator cover, turn on the power, and observe the visual motor check. "
During this the pump cannot be manually switched on. Push the tab on the top, and let the mechanism fall forward. I hope this helps. The problem lies, where the power dies, as they say, Thanks for the response. Does it need lubricant or something? Luis, it will, until it is switched to OFF, or until the OFF tripper shuts it off. First, secure the green ground wire to the green ground screw, then connect the other two wires to terminals #1 and #3. In this article, well cover what problems you may find with your Intermatic timer and how you can fix it without having to run to the store. Why do we stock so many pool parts? do i need to do something different? After a power failure the timer clock can start up backwards, mine has done this several times. Or is there anything else I can check? Open following links to identify timer and then add a comment. Ive seen it happen from lightning strikes, or insect infestation. Can breaker be bad? What happened? A wire inside the motor may be touching another wire, or the metal sides of the motor. Watch these tips and tricks before replacing it. View more property details, sales history and Zestimate data on Zillow. I have an intermatic timer thats 2 years young. Test the voltage coming in, it may be incorrect, or out of range (more than 10% above 110v or 220V). The A terminal is not normally used, unless you have a 3 wire service. please help me. The clock is powered from the Line 1 terminal correct? This pool timer is waterproof, heavy-duty, and accurate. Problems with Intermatic timers are caused by defective trippers, incorrect wiring, tripped circuit breakers, a faulty time clock motor and incorrectly set power terminals.